Agilent 1100 Hplc Setup Free To Call
A complete Agilent 1100 Series GPC-SEC Analyis system includes Column temperature stability is guaranteed from 10 ?C below ambient to 80 ?C. The high flow precision and the excellent temperature stability of the Agilent 1100 Series thermostatted column compartment ensure highest accuracy and precision of molecular weight determinations. The precision of its isocratic solvent delivery system provides the constant, stable flow rate that is essential to maintain the high resolution of the GPC-SEC column. Email: infoaimanalytical.com.Users Guide Agilent Agilent 1290 Infinity LC System Agilent 1100/1200 HPLC ChemStation Operation Agilent Technologies 1200 Series HPLC Standard Agilent.The Agilent 1100 Series HPLC system is ideally suited to GPC-SEC analysis. Please feel free to call us with any configuration questions 88 or 30.
Agilent ChemStation Plus with GPC-SEC data analysis software 1100 Series variable wavelength detector (recommended for protein analysis) 1100 Series refractive index detector (recommended for synthetic macromolecules and polysaccharides) 1100 Series thermostatted column compartment
Agilent 1100 Hplc Setup Verification Procedures And
An extended choice of data evaluation methods: Complete with validation and automated instrument verification procedures and fully compliant with ISO/EN 13885 and DIN 55672 GPC standards Allows internal standard and detector delay corrections and includes narrow, broad, universal and integral calibration Provides interactive and automated GPC-SEC analysis including recalibration and GPC reporting


Typically only 12-ml internal volume per channel Hardware and software designed for easy setup, operation, maintenance and early recognition of problemsAgilent 1100 Series Vacuum Degasser?xcellent degassing capacity! Parts in contact with solvents are made of stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensuring long product lifetime
Peltier temperature control from 4 to 40 ?C for up to 100 2-ml vials containing thermally-labile samples (thermostatted version)Agilent 1100 Series Thermostatted Column Compartment?xcellent temperature stability! No loss of sample?he entire volume drawn from the vial is injected Low internal volume of 300 µl for minimum contribution to a system's total internal volume Continuous flow-through design means all parts in contact with sample are flushed during the run, minimizing carry-over to almost zero Reliable injections from 0.1 µl to 100 µl and easy adaptation to allow injection volumes up to 1500 µl for applications ranging from microbore to semipreparative chromatography High degassing capacity providing reduced baseline noise and quenching effects for fluorescence detection resulting in lower detection limits, and long-term baseline stabilityAgilent 1100 Series Autosampler? unique injection principle!
Optimal high-quality Rheodyne column switching valve with ceramic statorface assemblies for prolonged lifetimeAgilent 1100 Series Refractive Index Detector?he perfect partner for GPC-SEC! Optimized design with an internal volume contribution as low as 9 µl for lowest dispersion For more columns add second thermostat Space for up to three 30-cm columns.
Include application-specific column, EasyCal Vial calibration standards and instruction manualUV detectors?or UV-visible light-absorbing polymers! 2 start-up kits available?or organic-soluble polymers and for water-soluble polymers Built-in solvent recycle valve to minimize solvent usage GPC-SEC start-up kits?or a quick and easy start into the world of GPC-SEC!
Agilent 1100 Series diode array detector gives you the full power of sensitive detection and spectral information with highest resolution and stability. Agilent 1100 Series multiwavelength detectors lets you detect up to five different wavelengths simultaneously without sacrificing baseline stability